Mercurial > ~darius > hgwebdir.cgi > epro
view velib_python/streamcommand.py @ 14:60ead9b5fc1b
Mark temperature as invalid when <-20C as per spec.
Shows up as -25C on the unit I have when the sensor is not connected.
author | Daniel O'Connor <darius@dons.net.au> |
---|---|
date | Mon, 06 Dec 2021 11:26:20 +1030 |
parents | 9c0435a617db |
children |
line wrap: on
line source
#!/usr/bin/env python3 # -*- coding: utf-8 -*- ## @package dbus_vrm import logging logger = logging.getLogger(__name__) import codecs import threading import subprocess from time import sleep # Runs a command, and calls sendfeedback with the statusupdates. class StreamCommand(object): SIGNALS = { 1: "SIGHUP", 2: "SIGINT", 3: "SIGQUIT", 4: "SIGILL", 6: "SIGABRT", 7: "SIGBUS", 8: "SIGFPE", 9: "SIGKILL", 10: "SIGBUS", 11: "SIGSEGV", 12: "SIGSYS", 13: "SIGPIPE", 14: "SIGALRM", 15: "SIGTERM"} def run(self, command, timeout, feedbacksender): self.feedbacksender = feedbacksender self.returncode = None self.utf8_decoder = codecs.getdecoder("utf_8") self.latin1_decoder = codecs.getdecoder("latin1") def target(): logger.info('Thread started for running %s' % command) self.feedbacksender.send({"status": "starting"}) try: self.process = subprocess.Popen(command, stdout=subprocess.PIPE, stderr=subprocess.DEVNULL) except OSError as e: logger.info("Command %s could not be started, errno: %s, msg: %s" % (command, e.errno, e.strerror)) self.feedbacksender.send({"status": "error", "errormessage": "Could not start (errno %s, msg %s)" % (e.errno, e.strerror), "errorcode": 731}, finished=True) self.process = None return self.readandsend() thread = threading.Thread(target=target) thread.start() thread.join(timeout) if self.process is None: # Error message has already beent sent return None # Make sure to send all the output self.readandsend() if thread.is_alive(): logger.warning("Command %s will now be terminated because of timeout" % command) self.process.terminate() # TODO or should it be killed? thread.join() logger.warning("Command %s has been terminated" % command) r = {"status": "error", "errormessage": "Stopped by timeout", "errorcode": 732} elif self.process.returncode < 0: signal = -1 * self.process.returncode error = "Stopped with signal %d - %s" % (signal, self.SIGNALS.get(signal, "unknown")) logger.warning("Command %s abnormal stop. %s" % (command, error)) r = {"status": "error", "errorcode": 733, "errormessage": error} else: logger.info("Command %s execution completed. Exitcode %d" % (command, self.process.returncode)) r = {"status": "finished", "exitcode": self.process.returncode} self.feedbacksender.send(r, finished=True) return self.process.returncode def readandsend(self): # TODO: check that below code works OK with vup stdout encoding (UTF-8), including non-standard ASCII chars while True: self.process.stdout.flush() line = self.process.stdout.readline() try: unicode_line, _ = self.utf8_decoder(line) except UnicodeDecodeError: unicode_line, _ = self.latin1_decoder(line) # Max length on pubnub is 1800 chars, and output is much better readable with the bare eye # when sent per line. So no need to send it alltogether. self.feedbacksender.send({"status": "running", "xmloutput": unicode_line}) if line == b'' and self.process.poll() != None: break sleep(0.04)