Mercurial > ~darius > hgwebdir.cgi > epro
view velib_python/dbusdummyservice.py @ 14:60ead9b5fc1b
Mark temperature as invalid when <-20C as per spec.
Shows up as -25C on the unit I have when the sensor is not connected.
author | Daniel O'Connor <darius@dons.net.au> |
---|---|
date | Mon, 06 Dec 2021 11:26:20 +1030 |
parents | 9c0435a617db |
children |
line wrap: on
line source
#!/usr/bin/env python3 """ A class to put a simple service on the dbus, according to victron standards, with constantly updating paths. See example usage below. It is used to generate dummy data for other processes that rely on the dbus. See files in dbus_vebus_to_pvinverter/test and dbus_vrm/test for other usage examples. To change a value while testing, without stopping your dummy script and changing its initial value, write to the dummy data via the dbus. See example. https://github.com/victronenergy/dbus_vebus_to_pvinverter/tree/master/test """ from gi.repository import GLib import platform import argparse import logging import sys import os # our own packages sys.path.insert(1, os.path.join(os.path.dirname(__file__), '../ext/velib_python')) from vedbus import VeDbusService class DbusDummyService(object): def __init__(self, servicename, deviceinstance, paths, productname='Dummy product', connection='Dummy service'): self._dbusservice = VeDbusService(servicename) self._paths = paths logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance)) # Create the management objects, as specified in the ccgx dbus-api document self._dbusservice.add_path('/Mgmt/ProcessName', __file__) self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version()) self._dbusservice.add_path('/Mgmt/Connection', connection) # Create the mandatory objects self._dbusservice.add_path('/DeviceInstance', deviceinstance) self._dbusservice.add_path('/ProductId', 0) self._dbusservice.add_path('/ProductName', productname) self._dbusservice.add_path('/FirmwareVersion', 0) self._dbusservice.add_path('/HardwareVersion', 0) self._dbusservice.add_path('/Connected', 1) for path, settings in self._paths.items(): self._dbusservice.add_path( path, settings['initial'], writeable=True, onchangecallback=self._handlechangedvalue) GLib.timeout_add(1000, self._update) def _update(self): with self._dbusservice as s: for path, settings in self._paths.items(): if 'update' in settings: update = settings['update'] if callable(update): s[path] = update(path, s[path]) else: s[path] += update logging.debug("%s: %s" % (path, s[path])) return True def _handlechangedvalue(self, path, value): logging.debug("someone else updated %s to %s" % (path, value)) return True # accept the change # === All code below is to simply run it from the commandline for debugging purposes === # It will created a dbus service called com.victronenergy.pvinverter.output. # To try this on commandline, start this program in one terminal, and try these commands # from another terminal: # dbus com.victronenergy.pvinverter.output # dbus com.victronenergy.pvinverter.output /Ac/Energy/Forward GetValue # dbus com.victronenergy.pvinverter.output /Ac/Energy/Forward SetValue %20 # # Above examples use this dbus client: http://code.google.com/p/dbus-tools/wiki/DBusCli # See their manual to explain the % in %20 def main(): logging.basicConfig(level=logging.DEBUG) from dbus.mainloop.glib import DBusGMainLoop # Have a mainloop, so we can send/receive asynchronous calls to and from dbus DBusGMainLoop(set_as_default=True) pvac_output = DbusDummyService( servicename='com.victronenergy.dummyservice.ttyO1', deviceinstance=0, paths={ '/Ac/Energy/Forward': {'initial': 0, 'update': 1}, '/Position': {'initial': 0, 'update': 0}, '/Nonupdatingvalue/UseForTestingWritesForExample': {'initial': None}, '/DbusInvalid': {'initial': None} }) logging.info('Connected to dbus, and switching over to GLib.MainLoop() (= event based)') mainloop = GLib.MainLoop() mainloop.run() if __name__ == "__main__": main()