view eprodbus.py @ 28:ea07d14075e6 default tip

Remove superfluous statement.
author Daniel O'Connor <darius@dons.net.au>
date Tue, 21 Dec 2021 15:06:13 +1030
parents 64d0d5aaf329
children
line wrap: on
line source

#!/usr/bin/env python

# Read enerdrive ePro packets from serial port and update DBus with them
# Also logs to an sqlite3 DB every 60 seconds

import datetime
from dbus.mainloop.glib import DBusGMainLoop
import epro
import gobject
import logging
import os
import serial
import signal
import sqlite3
import sys

sys.path.insert(1, os.path.join(os.path.dirname(__file__), 'velib_python'))
from vedbus import VeDbusService
from ve_utils import exit_on_error

logger = logging.getLogger('eprodbus')
logger.setLevel(logging.INFO)

formatter = logging.Formatter('%(asctime)s - %(message)s')

ch = logging.StreamHandler()
ch.setFormatter(formatter)

logger.addHandler(ch)

logger.info(__file__ + " is starting up")

dbpath = '/home/root/vanlogger/log.db'
instance = 0

class eProUpdater:
    def __init__(self, dbusservice, s, dbh):
        self.log_queue = []
        self.dbusservice = dbusservice
        self.p = epro.Processor()
        self.s = s
        self.dbh = dbh
        gobject.io_add_watch(s.fileno(), gobject.IO_IN, lambda fd, userdata: exit_on_error(self.read_serial, fd, userdata))
        gobject.timeout_add(60000, exit_on_error, self.log_epro)

    def read_serial(self, fd, userdata):
        data = self.s.read(1024)

        logger.debug('Read %d bytes from serial port', len(data))
        self.p.process(data)

        while len(self.p.packets) > 0:
            # Process oldest packets first
            p = self.p.packets.pop(0)
            self.log_queue.append(p)
            logger.debug('%s', str(p))
            if type(p) == epro.StateOfCharge:
                self.dbusservice['/Soc'] = p.soc
            elif type(p) == epro.MainVoltage:
                self.dbusservice['/Dc/0/Voltage'] = p.volts
            elif type(p) == epro.BatteryCurrent:
                self.dbusservice['/Dc/0/Current'] = p.amps
            elif type(p) == epro.BatteryTemperature:
                self.dbusservice['/Dc/0/Temperature'] = p.temp
            elif type(p) == epro.AmpHours:
                self.dbusservice['/ConsumedAmphours'] = p.amphrs
            elif type(p) == epro.TimeRemaining:
                # ePro reports in minutes, Venus expects seconds
                if p.time >= 0:
                    self.dbusservice['/TimeToGo'] = p.time * 60
                else:
                    # Battery is charging
                    self.dbusservice['/TimeToGo'] = None
            elif type(p) == epro.AuxVoltage:
                self.dbusservice['/Dc/1/Voltage'] = p.volts
            elif type(p) == epro.MonitorStatus:
                self.dbusservice['/Alarms/LowVoltage'] = 2 if p.mainlv else 0
                self.dbusservice['/Alarms/HighVoltage'] = 2 if p.mainhv else 0
                self.dbusservice['/Alarms/LowStarterVoltage'] = 2 if p.auxlv else 0
                self.dbusservice['/Alarms/HighStarterVoltage'] = 2 if p.auxhv else 0
                self.dbusservice['/Alarms/LowSoc'] = 2 if p.batflat else 0
                self.dbusservice['/Settings/HasTemperature'] = 1 if p.tempsense else 0
        return True

    def log_epro(self):
        logger.debug('Logging epro data')
        # Check we have all the packets we need in the queue
        msgtypes = set([x.msgtype for x in self.log_queue])
        wantedtypes = set([
            epro.MainVoltage.MSGTYPE,
            epro.AmpHours.MSGTYPE,
            epro.BatteryCurrent.MSGTYPE,
            epro.StateOfCharge.MSGTYPE,
            epro.TimeRemaining.MSGTYPE,
            epro.BatteryTemperature.MSGTYPE,
            epro.MonitorStatus.MSGTYPE,
            epro.AuxVoltage.MSGTYPE,
            ])
        if msgtypes < wantedtypes:
            logger.debug('Didn\'t get all packet types required to log')
            return

        row = {}
        usedtypes = set()
        while len(self.log_queue) > 0:
            pkt = self.log_queue.pop() # Read latest packets first
            if pkt.msgtype == epro.MainVoltage.MSGTYPE:
                row['main_voltage'] = pkt.volts
            elif pkt.msgtype == epro.AmpHours.MSGTYPE:
                row['amp_hours'] = pkt.amphrs
            elif pkt.msgtype == epro.BatteryCurrent.MSGTYPE:
                row['battery_curr'] = pkt.amps
            elif pkt.msgtype == epro.StateOfCharge.MSGTYPE:
                row['state_of_charge'] = pkt.soc
            elif pkt.msgtype == epro.TimeRemaining.MSGTYPE:
                row['time_remaining'] = pkt.time
            elif pkt.msgtype == epro.BatteryTemperature.MSGTYPE:
                row['battery_temp'] = pkt.temp
            elif pkt.msgtype == epro.MonitorStatus.MSGTYPE:
                row['auto_sync_volts'] = pkt.autosyncvolt
                row['auto_sync_curr'] = pkt.autosyncamp
                row['e501'] = pkt.e501compat
                row['alarm_test'] = pkt.alarmtst
                row['light'] = pkt.backlight
                row['display_test'] = pkt.disptst
                row['temp_sensor'] = pkt.tempsense
                row['aux_hv'] = pkt.auxhv
                row['aux_lv'] = pkt.auxlv
                row['installer_lock'] = pkt.lock
                row['main_hv'] = pkt.mainhv
                row['main_lv'] = pkt.mainlv
                row['low_battery'] = pkt.lowbatalarm
                row['battery_flat'] = pkt.batflat
                row['battery_full'] = pkt.batfull
                row['battery_charged'] = pkt.charged
                row['no_sync'] = pkt.nosync
                row['monitor_reset'] = pkt.monreset
            elif pkt.msgtype == epro.AuxVoltage.MSGTYPE:
                row['aux_voltage'] = pkt.volts

            usedtypes.add(pkt.msgtype)
            if usedtypes >= wantedtypes:
                self.log_queue = []
                break

        logger.info('Got all packets, logging')
        cur = self.dbh.cursor()
        row['tstamp'] = int(datetime.datetime.now().strftime('%s'))
        cur.execute('INSERT INTO eprolog VALUES (:tstamp, :main_voltage, :aux_voltage, :battery_curr, :amp_hours, :state_of_charge, :time_remaining, :battery_temp, :auto_sync_volts, :auto_sync_curr, :e501, :alarm_test, :light, :display_test, :temp_sensor, :aux_hv, :aux_lv, :installer_lock, :main_hv, :main_lv, :low_battery, :battery_flat, :battery_full, :battery_charged, :no_sync, :monitor_reset)', row)
        self.dbh.commit()
        return True

def doexit(signum, frame):
    sys.exit(1)

def main():
    port = sys.argv[1]
    servicename = 'com.victronenergy.battery.' + port
    # Add signal handler to exit, otherwise we have to press ctrl-c twice to quit
    signal.signal(signal.SIGINT, doexit)

    DBusGMainLoop(set_as_default = True)

    dbusservice = VeDbusService(servicename)
    dbusservice.add_mandatory_paths(__file__, '1.0', 'Serial ' + port, instance, 0, 'Enerdrive ePro', '1.0', '1.0', 1)
    dbusservice.add_path('/Dc/0/Voltage', value = None)
    dbusservice.add_path('/Dc/0/Temperature', value = None)
    dbusservice.add_path('/Dc/0/Current', value = None)
    dbusservice.add_path('/Dc/1/Voltage', value = None)
    dbusservice.add_path('/Soc', value = None)
    dbusservice.add_path('/TimeToGo', value = None)
    dbusservice.add_path('/ConsumedAmphours', value = None)
    dbusservice.add_path('/Alarms/LowVoltage', value = 0)
    dbusservice.add_path('/Alarms/HighVoltage', value = 0)
    dbusservice.add_path('/Alarms/LowStarterVoltage', value = 0)
    dbusservice.add_path('/Alarms/HighStarterVoltage', value = 0)
    dbusservice.add_path('/Alarms/LowSoc', value = 0)
    dbusservice.add_path('/Settings/HasTemperature', value = 0)

    s = serial.Serial('/dev/' + port, 2400, parity = 'E')
    s.timeout = 0.1

    dbh = sqlite3.connect(dbpath)

    updater = eProUpdater(dbusservice, s, dbh)

    logger.info('Starting main loop')
    mainloop = gobject.MainLoop()
    mainloop.run()

if __name__ == '__main__':